Drill Pipe Selection Guide


The main factors considered in the drill pipe selection are the collapse load, and the tensile load on the pipe. Burst pressures are not generally considered since these only occur when pressuring up the string on a plugged bit nozzle or during a DST, but it is very unlikely that the burst resistance of the pipe will be exceeded. Torsion need not be considered except in a highly deviated well. Once the collapse and tension load have been quantified, the appropriated weight and grade of drillpipe can be selected.

Collapse Load Factor for Drill Pipe Selection

The highest external pressure tending to collapse the string will occur at the bottom when the string is run empty into the hole. (This only occurs when running a Drillstem Test – DST tool). If a non-return valve is run (preventing upward flow of fluid into the drill pipe) it is normally standard practice to fill up the pipe at regular intervals when running in. The highest anticipated external pressure on the pipe is given by

Pc = 0.052 x MW x TVD
where:
Pc = collapse pressure (psi)
MW = mud weight (ppg)
TVD = true vertical depth (ft) at which Pc acts

This assumes that there is no fluid inside the pipe to resist the external pressure (i.e. no back up). The collapse resistance of new and used drillpipe are given in Tables drill pipe data. The collapse resistance of the drillpipe is generally derated by a design factor (i.e. divide the collapse rating by 1.125). A suitable grade and weight of drill pipe must be selected whose derated collapse resistance is greater than Pc. This string must then be checked for tension.

Tension Load for Drill Pipe Selection

The tensile resistance of drill pipe, as given in Table 11 and 12 is usually derated by a design factor (i.e. divide the tension rating by 1.15). The tension loading can be calculated from the known weights of the drill collars and drill pipe below the point of interest. The effect of buoyancy on the drillstring weight, and therefore the tension, must also be considered. Buoyancy forces are exerted on exposed horizontal surfaces and may act upwards or downwards. These exposed surfaces occur where there is a change in cross-sectional area between different sections (Figure Axial Load on the Drill String). By starting at the bottom of the string and working up to the top, the tension loading can be determined for each depth. This is represented graphically by the tension loading line (Figure Axial Load on the Drill String). If the drillpipe is to remain in tension throughout the drilling process, drill collars will have to be added to the bottom of the drill string. The bouyant weight of the drill collars must exceed the bouyant force on the drill pipe and the neutral point shown in Figure below must be within the length of the drill collars. The drill collars required to provide WOB discussed above must be added to the drill collars required to maintain the drill string in tension.

When do drill pipe selection, the maximum tensile load that the string could be subjected to will have to be considered. In addition to the design load calculated on the basis of the string hanging freely in the wellbore the following safety factors and
margins are generally added:

  • Design Factor – a design factor is generally added to the loading line calculated above (multiply by 1.3). This allows for extra loads due to rapid acceleration of the pipe.
  • Margin of Overpull – a “margin of overpull” (MOP) is generally added to the loading line calculated above. This allows for the extra forces applied to the drill string when pulling on stuck pipe. The MOP is the tension in excess of the drill string weight which is exerted. The MOP may be 50,000 – 100,000 lbs
Axial Load on the Drillstring on Drill Pipe Selection

Axial Load on the Drill String

  • Safety Factor – a safety factor for slip crushing is generally added to the loading line calculated above. This allows for the interaction of hoop stress (Sh) caused by the slips and the tensile stress (St) caused by the weight of the string. This effect reduces the allowable tension load by a factor (Sh/St) which can be calculated as

follows:

safety factor for slip crushing formula

safety factor for slip crushing

where:
D = O.D. of pipe (in)
L = length of slips (in)
K = lateral load factor
Slips are normally either 12 in. or 16 in. long, and for normally lubricated slips K = 4.00. Table 9 gives a direct result for Sh/St, but this assumes new pipe. If used pipe is being considered the actual D must be measured and Sh/St calculated from the above equation. Having obtained this factor it is applied to the tension loading line.

Thanks for read Drill Pipe Selection Guide  find other article for drilling on drilling engineering category. Please bookmark our site by type ctrl + D .

Tags:

Rate this article!

author

Author: 

Hero Santoso Effendi Petroleum Engineer From Indonesia, working on oil and gas industry. Bachelor Degree on Petroleum Engineer UPN Veteran Yogyakarta University. Working and learning hard sharing for complete my life. Programmer is my other skill. Find Me on Link below :

Related Posts